Neonatal Resuscitation Simulator

ModelTYE9048
Product size(mm)580*370*260

Outline

This simulator is a realistic full-term male newborn baby with anatomical accuracy and product features designed to focus on the critical resuscitation skills required in the first ten minutes of a newborn’s life, it meets the key components of the Neonatal Resuscitation Program and most other neonatal clinical training curricula.

Skills Gained

Infant CPR

Tracheal intubation 

Positive pressure ventilation

Sellick maneuver

Airway clearance

Umbilical vein intubation and administration 

Infant holding method

 

Features

Anatomy

Baby: anterior fontanel, posterior fontanel, inferior angle of scapula, umbilical cord, genitalia, etc.

Flexible joints such as bilateral shoulder, elbow, hip, etc.

Airway: tongue, palate, epiglottis, esophagus upper orifice , vocal cordstrachea, etc.

Realism: realistic tactile impression

Key Features:

1. Flexible joints allow for pronation and supination of the limbs.

2. If the newborn's head is not supported when being held, the neck may display a hyperextension effect, and the newborn's head may passively complete the extension, pitching and bending motions.

3. The model can be placed in the nasal aspiration position, and a 10F suction tube can clear the airway through the mouth and nose.

4. The contours of the face can fit well with the mask to ensure no air leakage during ventilation.

5. The accurate airway structure fully shows the characteristics of newborns, the epiglottis is long with a clockwise rotating "C" shape, and the epiglottis is above the oral axis, and the epiglottis is above the oral axis. Tracheal intubation can be accomplished with a 3.0 mm endotracheal tube (without cuff). The head can be tilted back to open the airway and the glottis can be easily visualized during the sellick maneuver.

6. Positive-pressure ventilation can be performed using BVM. It can also be operated by connect a bag after successful tracheal intubation.  

7. The model can be connected with T-piece resuscitator for continuous positive pressure ventilation. The error range between the detected PIP, PEEP by the T-piece and correction value is not more than ±2.

8. Neonatal chest compression can be performed, the compression depth should be at least one-third of the anterior and posterior diameter of the thorax, and two thumb-encircling hands technique can be practiced.

9. The simulated umbilical cord contains 2 umbilical arteries and 1 umbilical vein that can be seen in the cross-section, the simulated blood can flow out continuously. The umbilical artery can be palpated. Intubation is available in umbilical vein, the depth of intubation should not be less than 5 cm below the root of the umbilicus. It supports the operation of real drug administration in umbilical vein.

10. The umbilical cord is replaceable, can be cut, and supports ligation and stump care.

11. Various clinical operation scenarios are supported.